Digital Corrosion Test Meter AMT810E    
Introduction:
AMT810E Portable Fast Electrochemical Corrosion Meter is a simple operation instrument that integrates the Electrochemical Impedance Spectroscopy (EIS) measuring principle and is portable designed for fast measurements and directly display results. EIS measurement is employed to measure the solution resistance (Rs) and the polarization resistance (Rp) and further to calculate the corrosion rate.
Applications:
1. Corrosion rate monitor and corrosion inhibitor selection in the petroleum and chemical industry and road and bridge construction site.
2. Metal corrosion rate monitor in oil wastewater, soil, concrete and so on to evaluate corrosion protection countermeasures.
Specifications:
1. Probe channels: 1
2. Input impedance: 1011Ω
3. Potential range: ±2.5V
4. Potential resolution: 0.1mV
5. Rs range: 10Ω~500KΩ
6. Rp range: 5Ω~10MΩ
7. Corrosion rate: 0.1um ~ 10mm/a
8. Absolute Measurement Accuracy: <±1%
9. Sine wave amplitude: 1~100mV
10.Sine wave frequency: 10KHz~0.001Hz
11.Timing interval: 1~255h
12.Data storage: 10,000
13.Clock error: ±1min/month
14.Power: AC 220V/DC 1.5V(4 AA cell)
15.Dimensions: 260x165x20mm,Weight:3.5Kg
16.Temperature: -10~50°C, relative humidity:<80%, away from corrosive gas

              
XS-100 Rebar Corrosion Detection            
Features:
1. Easy to operate, fast and accurate read. The result is displayed with numbers or graphics.
2. Displays rebar corrosion degree with 9-level grey or colorful graphics
3. Measured data is inputted to PC software from USB interface.
4. Easy to operate, have concise software interface, have powerful analytical processing, can obtain testing report directly.
Brief introduction
XS-100 rebar corrosion detection is NDT instrument which tests rebar corrosion in the concrete structure. Using electrochemistry method, do the functions for corrosion detection, data analysis, storage and output etc. It is a detection instrument which is handed, measurement accurately and easy to use.
SPECIFICATIONS:
1. Potential electrode: Φ37X127mm
2. Electrode weight: 200g
3. Power supply: Alkaline cell X 6
4. Potential measurement range: ±1000mv
5. Test Accuracy: 1mv
6. Distance of test point: 0~1000mm
7. Data storage capacity: 50000 test points, 5000 test areas
8. Usage temperature range: -10°C ~ 40°C
9. Size: 220*145*60mm
              
Rebar Locators and Corrosion Test Meter GX50B      
Features:
Integrate the functions of rebar position test, concrete thickness test, rebar diameter test and rebar corrosion degree test into one product.
Brief introduction
1. Testing concrete cover thickness
2. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
3. Estimation bar diameter
4. Detection of Cable and Plumbing pipe
5. Detection of steel corrosion extent
SPECIFICATIONS FOR REBAR LOCATOR:
1. Bar diameter application range: Φ6 ~ Φ50mm
2. Maximum value permissible error of Bar diameter: ≤±1mm
3. Protective layer thickness measuring range:
1) The first measuring range: 6 ~ 90mm
2) The second measuring range: 7 ~ 180mm
4. The maximum error of reinforced protective layer thickness test value
1) The first measuring range 6~59mm; The second measuring range 7 ~ 79mm: ≤±1
2) The first measuring range 60~69mm; The second measuring range 80 ~ 119mm: ≤±2
3) The first measuring range 70~90mm; The second measuring range 120 ~ 180mm: ≤±4
5. Work temperature: -10 - +40; relative humidity RH: < 90%
6. Power supply mode: Alkaline cell x 6
SPECIFICATIONS FOR REBAR CORROSION:
1. Measuring Potential: ±2000mV
2. Test accuracy: ±1mV
3. Measuring Space: 1-99cm (adjustable)
4. Ambient Temperature: -10°C ~ +40°C
5. Environment Requirement: to avoid direct exposure to the sun for a long time.
6. Relative Humidity: <90%RH
7. Electromagnetic Interference: no strong alternating electromagnetic field
              
Rebar Locators and Corrosion Test Meter R71      
Features:
Integrate the functions of rebar position test, concrete thickness test, rebar diameter test and rebar corrosion degree test into one product.
Brief introduction
1. Testing concrete cover thickness
2. Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
3. Estimation bar diameter
4. Detection of Cable and Plumbing pipe
5. Detection of steel corrosion extent
SPECIFICATIONS FOR REBAR LOCATOR:
1. Bar diameter application range: Φ6 ~ Φ50mm
2. Maximum value permissible error of Bar diameter: ≤±1mm
3. Protective layer thickness measuring range:
1) The first measuring range: 6 ~ 90mm
2) The second measuring range: 7 ~ 180mm
4. The maximum error of reinforced protective layer thickness test value
1) The first measuring range 6~59mm; The second measuring range 7 ~ 79mm: ≤±1
2) The first measuring range 60~69mm; The second measuring range 80 ~ 119mm: ≤±2
3) The first measuring range 70~90mm; The second measuring range 120 ~ 180mm: ≤±4
5. Work temperature: -10 - +40; relative humidity RH: < 90%
6. Power supply mode: Alkaline cell x 6

SPECIFICATIONS FOR REBAR CORROSION:
1. Measuring Potential: ±2000mV
2. Test accuracy: ±1mV
3. Measuring Space: 1-99cm (adjustable)
4. Ambient Temperature: -10°C ~ +40°C
5. Environment Requirement: to avoid direct exposure to the sun for a long time.
6. Relative Humidity: <90%RH
7. Electromagnetic Interference: no strong alternating electromagnetic field