Film Coating Thickness Gauge

                                          
Paint Coating Thickness Meter EM2271                                    

Specifications:

1. Measuring Range: 0.0 ~ 2.0mm, 0 ~ 80mil

2. Accuracy: 2% rdg+-0.1mm, or 2%rdg+-4mil

3. Note: Accuracy is guaranteed at the operating temp. 23°C ±5°C, and relative humidity of not more than 75%.

4. Resolution: 0.1mm/1mil

5. Power Supply: 3V button cell, CR2032

6. Operation environment: temperature: 0 to 40°C; relative humidity:<80%

7. Size: 6.9*3.8*2cm

8. Weight: about 23g

                                          
Coating Thickness Meter AMT15                                    

Features:

1. Non-magnetic coatings (e.g. paint, zinc) on steel

2. Insulating coatings (e.g. paint) on no-ferrous metals

3. No-ferrous metals coatings on insulating substrates

4. Menu operation system

5. Two measuring mode: CONTINUE and SINGLE mode

6. Two working Mode: DIRECT and GROUP mode

7. Statistic Display: AVG, MAX, MIN, NO., S. DEV

8. One point calibrating, two points calibrating and basic calibrating easily

9. Memory for 400 readings(80 DIRECT and 320 GROUP readings)

10. Delete single readings and all group readings easily

11. High alarm and Low alarm for all working mode

12. Low battery, error indication

13. USB interface for PC software (windows 98/2000/xp/vista)

Specifications:

Sensor probe

F

N

Working principle

magnetic induction

Eddy current principle

Measuring range

0~1250um

0~1250um

Guaranteed tolerance (of reading)

(+/- 3%+1)um

(+/- 3%+1.5)um

Low range Precision

0.1um

0.1um

Minimum curvature radius

1.5mm

3mm

Diameter of Minimum area

3mm

5mm

Basic critical thickness

0.5mm

0.3mm

Size (HxWxD)

113.5mm x 54mm x 27mm

Weight

110g

                                      
Coating Thickness Meter AMT15A                          

Features:

1. Non-magnetic coatings (e.g. paint, zinc) on steel

2. Insulating coatings (e.g. paint) on no-ferrous metals

3. No-ferrous metals coatings on insulating substrates

4. Menu operation system

5. Two measuring mode: CONTINUE and SINGLE mode

6. Two working Mode: DIRECT and GROUP mode

7. Statistic Display: AVG, MAX, MIN, NO., S.DEV

8. One point calibrating, two points calibrating and basic calibrating easily

9. Memory for 400 readings(80 DIRECT and 320 GROUP readings)

10. Delete single readings and all group readings easily

11. High alarm and Low alarm for all working mode

12. Low battery, error indication

13. USB interface for PC software (windows 98/2000/xp/vista)

Specifications:
                                      
Mini Film Coating Thickness Meter AMF066                         
Measurement ranges: 0~1.80mm/0~71.0mil
Resolution: 0.01mm/1mil
Measurement error: ±0.03mm
Min. diameter of substrate: 50mm
Min. thickness of substrate: 0.5mm
Power supply: 2*1.5V AAA batteries
Operating temperature range 0~40℃
Operating humidity range: 10~95%RH
Overall dimensions: 61.98*30.57*104.99cm
Weight: 63.98g
Standard Quantity Per Carton: 60PCS
Standard Carton Size: 49.7x 49 x 45.3cm

                                      
Mini Film Coating Thickness Meter AMF067                         
Measurement ranges:0~1800μm/0~70.9mil
Resolution:0.1μm/1μm/1mil
Measurement error:±(3%H+1μm)
Min. diameter of substrate:Φ12mm
Min. thickness of substrate:0.5mm
Min. curvature radius of convex substrate:2mm
Min. curvature radius of concave substrate:11mm
Power supply:2*1.5V AAA batteries
Operating temperature range 0~40°C
Operating humidity range:10~95%RH
Overall dimensions:61.98*30.57*104.99mm
Weight:63.98g
Standard Quantity Per Carton:20PCS
Standard Carton Size:65.9*44*28.9cm

                                      
Film Coating Thickness Gauge AMF021                         
*Measuring range: 0~1800µm
*Accuracy: ±3%H±1µm
*Resolution: 0.1µm (<100µm) or 1µm(>100µm)
*Use Hi-sensibility sensor for precise measurement
*Zero point, two point and basic, three different calibration
*Measuring mode: Single, Continually and Difference
*Data store/ Data recall/ Data delete function
*Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times
*Beep sound indication
*Measure in Metric/Imperial
*LCD backlight display
*Low battery indication
*Auto power off
*Packing method: Gift box + PP box
*Power supply: 9V battery
*Weight: 147g (without battery)
*Dimension: 67*30*183mm

                                      
Film Coating Thickness Gauge AMF022                         
*Measuring range: 0~1500µm
*Accuracy: ±3%H±1µm
*Resolution: 0.1µm (<100µm) or 1µm(>100µm)
*Use Hi-sensibility sensor for precise measurement
*Zero point, two point and basic, three different calibration
*Measuring mode: Single, Continually and Difference
*Data store/ Data recall/ Data delete function
*Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times
*Beep sound indication
*Measure in Metric/Imperial
*LCD backlight display
*Low battery indication
*Auto power off
*Packing method: Gift box + PP box
*Power supply: 3*1.5V AAA battery
*Weight: 250g (without battery)
*Dimension: 70*145*28mm
*Accuracy: ±3%H±1µm

                                      
Film Coating Thickness Gauge AMF022F                         
*Measuring range: 0~1800µm
*Accuracy: ±3%H±1µm
*Resolution: 0.1µm (<100µm) or 1µm(>100µm)
*Use Hi-sensibility sensor for precise measurement
*Zero point, two point and basic, three different calibration
*Measuring mode: Single, Continually and Difference
*Data store/ Data recall/ Data delete function
*Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times
*Beep sound indication
*Measure in Metric/Imperial
*LCD backlight display
*Low battery indication
*Auto power off
*Warranty: 12months
*Packing method: Gift box + PP box
*Power supply: 9V battery
*Weight: 220g (without battery)
*Dimension: 70*145*28mm

                                      
Coating Thickness Meter MCT200                         
Order Number: MCT200 (with F1, N1 probe); MCT200F (with F1 probe), MCT200N (with N1 Probe)

 

Features:

1. With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non magnetic metal substrate.
2. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm.
3. Two measuring modes: single or continuous, changeable.
4. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method.
5. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions.
6. Measuring status indicator showing the measuring status.
7. The gauges’ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation.
8. Battery information indicates the rest capacity of the battery.
9. Auto sleep and auto power off function to conserve battery life.
10. USB1.1 communication port. Optional software to process the memory data on the PC.
11. Compact aluminum case, suitable for use under poor working conditions

 
Specifications:
1. Measuring principle: Magnetic induction & Eddy current
2. Measuring range: 0~1250μm, depends on probes. maximum 10mm for the probe F10.
3. Low range resolution: 0.1μm
4. Accuracy: ±(3%Thickness+1)μm, depends on probes and conditions
5. Display: 4 digits LCD with EL backlight
6. Memory for up to 20 files (up to 50 values for each file) of stored values.
7. Unit system: Metric (μm), Imperial (mil)
8. Power source: Two “AA” size, 1.5 Volt alkaline batteries. 200 hours typical operating time (EL backlight off).
9. Communication: USB1.1
10. Dimensions: 125 x 67 x 31 mm
11. Weight:340g
                                        
Coating Thickness Meter TIME2600                                     
Order Number:
TIME2600: with F1, N1 probe
TIME2600F: with F1 probe
TIME2600N: with N1 probe
TIME2600F4: with F400 probe
TIME2600F19: with F1/90 probe
TIME2600CN: with CN02 probe

Product Introduction:
TIME2600 Coating Thickness Gauge can nondestructively measure the thickness of non-magnetic coatings (such as zinc, aluminum chrome, copper, rubber, paint and so on) on ferrous metals (such as steel, iron, alloyed metals, hard magnetic steel and so on). It can also measure the thickness of non-conducting coatings (such as rubber, paint, plastic, anode oxide film and so on) on the non-ferrous materials (such as copper, aluminum, zinc, tin and so on). It can fast, exactly and nondestructively measure the thickness of coating and plating.

Features
1. Two measuring methods: magnetic induction (F) and eddy current (N). When F probe is equipped, it can measure the non-magnetic coating in magnetism substrate, when N probe is equipped, it measure the non-conductive coating on non-magnetism substrate.
2. 6 types of probes are available for various applications:F400, F1, F1/90, F10, N1, CN02
3. 2 measurement modes: continuous / single
4. 5 statistical ways: Mean values / Max. values / Min. values / testing numbers. (No.) / standard deviations (S.DeV)
5. 640 measured values can be stored
6. Integrated with printer for convenient use
7. Low battery indication
8. 2 switch off modes: manual and auto
Technical Specification
1. Standards: DIN, ISO, ASTM, BS
2. Calibration: Zero and foil calibration
3. Data memory: 640 readings
4. Statistics: Number of measurements, mean, standard deviation, maximum and minimum of 3000 readings
5. Data memory: 640 readings
6. Limits: Adjustable with alarm
7. Interface: RS-232
8. Working temperature: 0~40℃
9. Power supply: NiMH Rechargeable batteries 1.25V
10. Dimensions: 230 x 86 x 47mm
11. Weight: Approx. 530g

Optional probes and technical specification

Probe model F400 F1 F1/90º F10 N1 CN02
Operating principle Magnetic induction Eddy current
Measuring range (µm) 0-400 0-1250 0-10000 0 to 1250μm
0 to 40μm (for chrome plate on copper)
10~200
Low range resolution (µm) 0.1 0.1 10 0.1 1
Accuracy One-point calibration (µm) ±(3%H+1) ±(3%H+10) ±(3%H+1.5) ±(3%H+1)
Two-point calibration (µm) ±[(1~3)H%+0.7] ±[(1~3)H%+1] ±[(1~3)%H+10] ±[(1~3)%H+1.5] -
Measuring conditions Min curvature of the min area (mm) Convex 1 1.5 Flatten 10 3 Flatten
Diameter of the min area (mm) φ3 φ7 φ7 φ40 φ5 φ7
Critical thickness of substrate (mm) 0.2 0.5 0.5 2 0.3 unlimited
                                        
Coating Thickness Meter CM-8855                                     
1.FEATURES
It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTM and  BS. It can be used both in the laboratory and in harsh field conditions.
The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magnetic
materials (e.g. iron, nickel etc.) . often used to measure the thickness of
galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, some alloy tile, paper etc.
The N probes measure the thickness of non-magnetic coatings on non-magnetic metals . It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
* Automatic substrate recognition.
* Manual or automatic shut down.
* Two measurement mode: Single and Continuous
* Wide measuring range and high resolution.
* Metric/Imperial conversion.
* Digital backlit display gives exact reading with no guessing or errors.
* Can communicate with PC computer for statistics and printing by the optional cable.
* Can store 99 groups of measurements.
* Statistics is available.
2.SPECIFICATIONS
Display: 4 digits LCD, backlight
Range: 0~1250μm/0~50mil (other ranges can be specified )
Min. radius work piece: F: Convex 1.5mm/Concave 25mm; N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min. Sample thickness : 0.3mm
Resolution: 0.1μm (0~99.9μm); 1μm (over 100μm)
Accuracy: ±1~3%n or 2.5μm or 0.1mil (Whichever is the greater)
Battery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50℃ . 
Humidity <95% .
Size: 126x65x35 mm;  5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth  interface
                                        
Coating Thickness Meter CM-8856                                     
1.FEATURES
It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTM and BS. It can be used both in the laboratory and in harsh field conditions.
* The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminum tile, some alloy tile, paper etc.
The N probes measure the thickness of non-magnetic coatings on non-magnetic metals . It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
* Automatic substrate recognition.
* Manual or automatic shut down.
* Two measurement mode: Single and Continuous
* Wide measuring range and high resolution.
* Metric/Imperial conversion.
* Digital backlit display gives exact reading with no guessing or errors.
* Can communicate with PC computer for statistics and printing by the optional cable.
* Can store 99 groups of measurements.
* Statistics is available.
2.SPECIFICATIONS
Display: 4 digits LCD, backlight
Range: 0~1250μm/0~50mil (other ranges can be specified)
Min. radius work piece: F: Convex 1.5mm/Concave 25mm; N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min. Sample thickness : 0.3mm
Resolution: 0.1μm (0~99.9μm); 1μm (over 100μm)
Accuracy: ±1~3%n or 2.5μm or 0.1mil (Whichever is the greater)
Battery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50℃ . 
Humidity <95% .
Size: 126x65x35 mm;  5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth  interface
                                          
Coating Thickness Meter CM-8829F, CM-8829N, CM-8829FN    
Operating principle: magnetic induction / eddy current
Measuring range: 0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: ±1-3%n or ±2.5um
Min. measuring area: 6mm
Min. sample thickness: 0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4 x 1.5V AAA (UM-4) battery
Auto power off
Operating conditions:0 ~ +45℃ (32℉-104℉), 90%RH max
Dimensions: 126x65x27mm
weight: 81g (not including battery)
Optional accessories: other range 0-200um to 15000um

                                        
Coating Thickness Meter CM-8829SF, CM-8829SN, CM-8829SFN    
Application: used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks etc. in industries of petroleum, shipbuilding, power station and machine manufacturing.
With separate probe (s)
Operating principle: magnetic induction/eddy current (F/NF)
Measuring range:0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: ±1-3%n or ±2.5um
Min. measuring area:6mm
Min. sample thickness:0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4x1.5V AAA(UM-4)battery
Auto power off
Operating conditions:0-+45℃(32℉-104℉),≤90%RH
Dimensions: 126x65x27mm
weight: 81g(not including battery)
Optional accessories: other range 0-200um to 15000um
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth  interface
                                        
Coating Thickness Meter CM-8828F, CM-8828N, CM-8828FN    
Operating principle: magnetic induction / eddy current
Measuring range: 0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: ±1-3%n or ±2.5um
Min. measuring area: 6mm
Min. sample thickness: 0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4 x 1.5V AAA (UM-4) battery
Auto power off
Operating conditions:0 ~ +45℃ (32℉-104℉), 90%RH max
Dimensions: 126x65x27mm
weight: 81g (not including battery)
Optional accessories: other range 0-200um to 15000um

                                        
Coating Thickness Meter CM-8826F, CM-8826N, CM-8826FN    
Operating principle: magnetic induction / eddy current
Measuring range: 0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: ±1-3%n or ±2.5um
Min. measuring area: 6mm
Min. sample thickness: 0.3mm
Battery indicator: low battery indicator
Metric/ imperial: convertible
Power supply: 4 x 1.5V AAA (UM-4) battery
Auto power off
Operating conditions:0 ~ +45℃ (32℉-104℉), 90%RH max
Dimensions: 126x65x27mm
weight: 81g (not including battery)
Optional accessories: other range 0-200um to 15000um

                                        
Coating Thickness Meter CM-8825F, CM-8825N, CM-8825FN    
Operating principle: magnetic induction/eddy current (F/NF)
Measuring range: 0-1250um/0-50mil
Resolution: 0.1/1
Accuracy: ±1-3%n or ±2.5um
Min. measuring area: 6mm
Min. sample thickness: 0.3mm
Battery indicator: low battery indicator
Metric/imperial: convertible
Power supply: 4x1.5V AAA(UM-4) battery
Auto power off
Operating conditions:0-+45℃ (32℉-104℉), 90%RH max
Dimensions: 126 x 65 x 27mm
weight: 81g (not including battery)
Optional accessories: other range 0-200um to 15000um