LUX Meter 
 
DIGITAL LUX METER  LX-9626          
Application: widely used in electro-optical sources, research teaching, metallurgy building, industry inspection as well as agriculture researching and illumination control.
Measuring range: 0-50000LUX 0-5000FC
3 RANGE: x1,x10,x100
Resolution: 1
Accuracy: ±5%n
HOLD
Band pass filter
Overload indication: 1
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 97x53x17mm
Weight (not including probe): 183g
 
DIGITAL LUX METER  LX-9621          
Application: widely used in electro-optical sources, research teaching, metallurgy building, industry inspection as well as agriculture researching and illumination control.
Measuring range: 0-50000LUX
3 RANGE: x1,x10,x100
Resolution: 1
Accuracy: ±5%n
HOLD
Band pass filter
Overload indication: 1
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 97x53x17mm
Weight (not including probe): 174g
 
DIGITAL LUX METER  LX-101          
Application: widely used in electro-optical sources, research teaching, metallurgy building, industry inspection as well as agriculture researching and illumination control.
Measuring range: 0-50000LUX
3 RANGE: x1,x10,x100
Resolution: 1
Accuracy: ±5%n
HOLD
Band pass filter
Overload indication: 1
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 97x53x17mm
Weight (not including probe): 174g
 
DIGITAL LUX METER  LX-80          
SPECIFICATION:
♦ Displays environmental illuminance in LCD
♦ Large Range: 1~200,000lux
♦ Accuracy up to ± 4%
♦ Resolution: 1lux / 0.1Fc
♦ Use for visible light measurement
♦ Unit: Lux / Fc
♦ Range Selecting: AUTO or Manual
♦ MAX / MIN Modes for choosing
♦ Impact proof housing
♦ Auto power off conserves battery energy
♦ Data Hold function
♦ Built-in battery check & low battery icon display
♦ Complete with protective cap, and 9V battery

 
DIGITAL LUX METER  AMF023          
SPECIFICATION:
*Measuring range: 0~200000Lux, 0~185806Fc
*Accuracy: ±3% (<10,000Lux); ±4% (>10,000Lux)
*Response time: 0.5s
*Photometric sensor: Silicon diode
*Operating temperature and humidity: 0℃~40℃, 10%RH ~ 90%RH
*Storage temperature and humidity: -20℃~50℃, 10%RH ~ 90%RH
*Power:9Vbattery
*Unit size:52.5*35.5*166mm
*Net weight: 110.4g
*LUX (Lux) / FC (footcandles) Unit
*Selection function
*After 5 minute auto power off
*Backlight function
*Maximum and minimum measurements
*Automatic measurement function (AUTO)
*Data rise and fall time is short
*Low battery indication

 
DIGITAL LUX METER            
Order No.: AMA001

AMA002 with 270° adjustable sensor
SPECIFICATIONS:
●Double Parameter Measurement: Lux (lm/m²); foot candle (lm/ft²)
●Range: 0~30000 Lux; 0~2788.0 ftc
●Resolution: 1 Lux; 0.1 ftc
●Accuracy: ±4%
●Sample rate: 1 time/sec
●Auto power off: about 20 minutes
●Operating environment: 0~+50℃(32~+122°F), 0~80%RH
●Storage environment: -20~+60℃(-4~+140°F), 0~80%RH
●Special function: Auto power off with disable feature; Data hold; MAX MIN; Back light
●Power Supply: DC1.5V (AAA) x 3pcs
●Dimension:121(L) x 60(W) x 30(H)mm
●Weight: about 180g
 
LUX METER LX1010B          
1. Display: 3 1/2 digits LCD display, maximum reading; value display 1999
2. Accuracy: <10,000Lux:±4%rdg±0.5f.s; >10,000Lux:±5%rdg±10digits (Calibrated to standard incandescent lamp at color temperature 2856K)
3. Ranges:1~100,000Lux.(3 Ranges); 20,000Lux range: reading x10; 100,000Lux range: reading x100
4. Resolution: 1Lux
5. Repeatability: ±2%
6. Temperature Characteristic: ±0.1%
ºC
7. Sampling time: 0.5 second
8. Reading locked function
9. Photo detector: one silicon photo diode with filter.
10. Dimensions: 106 x 57 x 26mm (photo detector); 130 x 72 x 30mm (meter body)
 

                                     B

 
DIGITAL LUX METER LX1010BS         
3-1/2 digits 18mm LCD
Range: 1~100,000Lux
Accuracy: ≤10,000Lux, ±(4%rdg+10digit)
      >10,000Lux, ±(5%rdg+10digit)
Resolution: 1Lux
Repeatability: ± 2%
Temperature Characteristic: ± 0.1%/℃
Sampling Time: 0.5 second
Photo detector: one silicon photo
         diode with fliter
Dimensions: 130Lx72Wx30H(mm)
Over-input: Indication of “1”

 
AMTAST DIGITAL LUX METER LX-90 Fast Response      
3-1/2 digits 18mm LCD
Range: 1~100,000Lux
Accuracy: ≤10,000Lux, ±(4%rdg+10digit)
      >10,000Lux, ±(5%rdg+10digit)
Resolution: 1Lux
Repeatability: ± 2%
Temperature Characteristic: ± 0.1%/℃
Sampling Time: 0.5 second
Photo detector: one silicon photo
         diode with fliter
Dimensions: 130Lx72Wx30H(mm)
Over-input: Indication of “1”

 
DIGITAL LUX METER LX1020BS       
3-3/4 digits 18mm LCD
Range: 0.1~40,000Lux
Accuracy: ≤10,000Lux, ±(4%rdg+10digit)
      >10,000Lux, ±(5%rdg+10digit)
Resolution: 0.1Lux
Repeatability: ± 2%
Temperature Characteristic: ± 0.1%/℃
Sampling Time: 0.5 second
Photo detector: one silicon photo diode with fliter
Dimensions: 130Lx72Wx30H(mm)
Over-input: Indication of “OL”.
Peak hold.
 

 
DIGITAL LUX METER LX1330B       
3-1/2 digits 18mm LCD
Range: 0.1~200,000Lux/0.01~20,000FC
Over-input: Indication of “1”
Accuracy: ≤20,000Lux, ±(3%rdg+10digit); >20,000Lux, ±(5%rdg+10digit)
Resolution: 0.1Lux
Repeatability: ±2%
Temperature Characteristic: ±0.1%/℃
Sampling Time: 0.5second
Photo detector: one silicon photo diode with filter.
Dimensions: 160Lx79Wx43H(mm)
Date hold, peak hold
Display in Lux and FC switchable

                         

 
DIGITAL LUX METER LX1332B       
1. Display: 3 1/2 digits LCD display, maximum reading; value display 1999
2. Range gear: 200Lux, 2,000Lux, 20,000Lux, 200,000Lux, 20FC, 200FC, 2,000FC, 20,000FC; 20,000Lux range: reading x10; 200,000Lux range: reading x100; 20,000FC range: reading x10
3. Accuracy:±(4%rdg+10); >20,000Lux/2,000FC:±5%rdg±10digits (Calibrated to standard incandescent lamp at color temperature 2856K)
4. Repeatability: ±2%
5. Temperature Characteristic: ±0.1%/
ºC
6. Sampling time: 0.5 second
7. Photo detector: one silicon photo diode with filter.
8. Dimensions: 180L x 65W x 35Hmm
9. Reading locked function
10. Measuring probe can 270° whirl
                          
5 IN 1 Environment Tester AMF035                    
Features:
1. Rugged 5-in-1 environmental tester with tripod mount
2. Large dual LCD simultaneous display of Real-time Value and MAX/MIN/AVG/DIF(MAX-MIN) Value
3. Data Hold, MAX/MIN/AVG/DIF, Auto power off, Low Battery and Over Range indicators
4. Built-in low friction vane wheel improves accuracy or air velocity in CMM, CFM, m/s, km/h, FPM, knots
5. Built-in precision digital humidity and temperature sensor for fast response
6. Utilizes precision photo diode and correction filter for Cosine and color corrected light measurements
7. Sound Level measurement meets IEC61672 class 2 using A/C weighting and fast/slow sample rating modes

Specifications Range Resolution Accuracy
Temperature -10~60℃; 14~140℉ 0.1℃; 0.1℉ ±1℃; ±2℉
Humidity 20%~80% RH 0.1RH ±3.0% RH
Light 0~50000LUX 1LUX ±(5.0%+10)
Anemometer 0.4~20m/s 0.1m/s ±(3.0%+10)
1.4~72km/h 0.1km/s
1.3~65.7ft/s 0.1ft/h
0.8~38.9knots 0.1knots
Air Flow  0~999900CMM 0.1CMM
0~999900CFM 0.1CFM
Sound Level 30~130dB(A) 0.1dB ±1.5dB
 
UV LIGHT METER UV340B      
Measurable of UVA & UVB
LSI-circuit use provides high reliability and durability
3 3/4 LCD display, maximum indication 3,999
Range: 0~40mW/cm²

3 range: 400μW/cm²
, 4,000μW/cm², 40mW/cm²
UV sensor spectrum: 290~390nm
Accuracy: ±(4%FS+2 digit)
Sensor structure: The exclusive UV photo diode & UV color correction filter.
Sampling Time: 0.5 second
Operating Temperature: -10~40°C(14~104°F)
Operating Humidity: 0~70%Rh
Over-input: Indication of “OL”.
Peak hold.

 
UV LIGHT METER UVA365      
*Professional, high quality UV light meter
*Measurable of UVA
*UV detector spectrum: 320nm to 390nm.
*Four range selection switchable.
*Display: 3 3/4 LCD display, maximum reading 39990.
*Measurement Range: 0-400mW/cm²; Four range selectable: 400μW, 4000μW, 40mW, 400mW (1000 μW/cm² =1 mW/cm²)
*UV sensor spectrum: band pass 320nm ~ 390nm
*Accuracy: ±(4%FS + 2dgt) Calibration under the standard UVA light & and compare; Special tested under the environment RF Field Strength less than 3V/M & frequency less than the 30 MHz only
*Sensor structure: exclusive UV photo diode & UV color correction filter.
*Sample Time: 2.5 times/s.
*Over Range indication: ‘OL’
*Weight: 325g(include battery)
*Operating Temperature & Humidity: -10℃ to 40℃(32℉-104℉) 0~70%Rh
*Power Supply: DC 9V battery, 006P, MN 1604 (PP3) or equivalent.
*Power Consumption: Approx. DC 2.7mA
*Dimension: 165x50x32mm (photo detector); 160x78x43mm (meter body)
 
UVC LIGHT METER UVC254      
Features:
1. Professional and quality UV meter
2. Narrow-band spectrum 248nm~262nm, 254nm peak wavelength
3. Large scale integrated circuit ensures high precision and stability
4. UV probe comprises of visible light insulation diaphragm, narrow-band optical filter and gallium arsenide sensor.
5. Shell of aluminium alloy probe is equipped with fixed screw holes, which facilitates to measure to properly install the probe with ease.
6. Width of measuring span, 1uW/cm2~39.99mW/cm2

Scope:
The instrument is applicable to the measurement of UV radiation intensity in fields of sterilization, photoetching, water treatment, health care and breeding.

Specifications:
1. Wavelength coverage: 248nm~262nm
2. Peak wavelength: 254nm
3. Irradiance measuring span: 3999uW/cm2, 39.99mW/cm2
4. Resolution ratio: 1uW/cm2
5. Parasitic light beyond ultraviolent band: <0.1%
6. Accuracy: ±5% +2 words
7. Sampling rate: 2.5 times per second
8. Overload display: “OL”
9. Weight: 350g (Battery, probe included)
10. Power supply: DC 9V (6F22 type) battery
11. Operating current: about 2.7mA
12. Dimension: body 160x78x43mm; Sensorφ40x35mm

 
UV LIGHT METER UV126A      
UV126A is Suited for Radiation intensity measurement of UV light source, such as Ultraviolet curing lamp, Photolithography exposure, integrated circuit photolithography etc.
Specifications:
1).Accuracy: ± 10 %
2).Resolution: 0.01 mW/cm²
3).Response Wavelength: 320nm ~ 400nm; λp =365nm
4).Measuring range: 0-2000 mW/cm²
5).Probe size: 45mm*12.5mm (D*H)
6).Instrument size: 130mm * 70mm * 28mm (L*W*H )
7).Length of the probe wire: 1m
8).power supply: 4 AAA alkaline batteries
 
UV LIGHT METER UV126C      
UV126C is used to measure the UVC ultraviolet intensity, special for measuring Ultraviolet sterilization lamp.
Specifications:
1) Accuracy:±10%
2) Resolution: 0.1 uW/cm²
3) Response Wavelength: 230nm ~ 280nm, λp = 254nm
4) Measuring range: 0-200000 uW/cm²
5) Instrument size: 130mm * 70mm * 28mm (L*W*H)
6) Probe size:45mm*16mm (D*H)
7) The probe wire length: 1m
8) Power supply: 4 AAA alkaline batteries
Characteristic:
1) Use special UVC sensor filter to eliminate the effects of UVA and UVB rays.
2) Power down without loss of the last measurement data
 
UV INTEGRATOR UV150      
The UV-Integrator 150 is a high quality UV measuring instrument. It is widely used to measure UV energy of different light sources, especially on printing machines. It is ideal to ensure quality control of printing and drying processes.
Spectral Range: UV 250~410nm (peak at 330nm)
Measuring range: 0~5,000 MW/CM²
Display Range: 0~999,999 MJ/CM²
Power Source: 3.6V Battery
Power consumption:  100uA
Battery service life: 10,000 hours
Dimensions: 3.5" (90mm) Diameter x 0.5" (12mm) height
Weight:  150g
 
Solar Power Meter SM206      
Features:  
1. Selectable from two units: W/M² and Btu
2. Peak hold function
3. Data hold function
4. Measure directly without adjustment
5. Steadily measure for a long period

Specifications:
1. Resolution: 0.1W/M², 0.1Btu/(ft2-h)
2. Error range: ±10W/M²; ±3Btu/(ft2-h) or ±5% of the measured value
3. Temperature error: ±0.38W/M²/
ºC; ±0.12Btu/(ft2-h)/ºC; deviation at 25ºC
4. Display: 3-3/4 LCD display, maximum displayed numerical value 3999
4. Shift: <±3% /year
5. Overload display “OL”
6. Range: 0.1-399.9 W/M², 1-3999 W/M², 0.1-399.9 Btu/(ft2-h), 1-3999 Btu/(ft2-h)
7. Sampling time: 0.5 second
8. Operation temperature and humidity: 0°C to 50°C; <80%RH
9. Storage temperature and humidity: -10°C to 60°C; <70%RH
10. Dimensions and weight: 132 x 60 x 38mm
11. Weight: approx. 150g
12. Battery needed: 9V battery