refractometerS
                                          
Hand Held Type                                     
The Hand Held Refractometers are specially designed for measuring the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. And they can also test for the proportion of the water-soluble solution. They can be easily used and they are competitive in price. You only need to drop some liquid on the prism and then make it towards to the sunlight. Then the reading of the concentration will appear. ATC means Automatic Temperature Compensation.

 

 

Normal Hand Held Type

                                          
For Brix                                                  
Model Range Min.Div. Accuracy Remark
RHB0-80 Brix: 0-80% Brix: 0.5% Brix: ±0.5% Without ATC
RHB0-80S Brix: 0-80% Brix: 0.5% Brix: ±0.5% Without ATC
RHB0-90 Brix: 0-90% Brix: 0.2% Brix: ±0.2% Without ATC
RHB-90S 0-42%, 42-71%, 71-90% Brix: 0.2% Brix: ±0.2% ATC
RHB-10ATC Brix: 0-10% Brix: 0.1% Brix: ±0.10% ATC
RHB-18ATC Brix: 0-18% Brix: 0.1% Brix: ±0.10% ATC
RHB-20ATC Brix: 0-20% Brix: 0.1% Brix: ±0.10%  ATC
RHB-32ATC Brix: 0-32% Brix: 0.2% Brix: ±0.20% ATC
RHB-50ATC Brix: 0-50% Brix: 0.5% Brix: ±0.50% ATC
RHB58-92ATC Brix: 58-92% Brix: 0.5% Brix: ±0.5% ATC
RHB-62ATC Brix: 28-62% Brix: 0.2%x Brix: ±0.2% ATC
RHB-82ATC Brix: 45-82% Brix: 0.5% Brix: ±0.5% ATC
RHB-92ATC Brix: 58-92%
Baume: 38-43Be'
water: 12-27%
Brix: 0.5%
Baume: 0.5Be'
water: 1%
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%
ATC
                                          
For Beer                                           
Model Range Min. Div. Size N.W.
AMR008 Brix: 0~32% 0.2% 30x30x130mm 400g
SG: 1.000~1.120 0.001
                                          
For Salinity                                           
Model Range Min.Div. Accuracy Remark

RHSA-4ATC 

Salinity: 0-40‰
Gravity: 1.000-1.030 
Salinity: 1‰
Specific gravity: 0.001
Salinity:±1‰
Specific gravity: ±0.001
ATC, For Aquarium
RHS-10ATC Salinity: 0-100‰
Gravity: 1.000-1.070 
Salinity: 1‰
Gravity: 0.001
Salinity: ±0.001
Specific gravity: ±0.001 
ATC
RHS-10BATC Brix: 0-10%
Salinity: 0-100‰
Gravity: 1.000-1.070
Brix: 0.2%
Salinity: 1‰
Gravity: 0.001
Brix: ±0.2%
Salinity: ±1‰
Specific gravity: ±0.001
ATC
RHS-28ATC Salinity: 0-28% Salinity: 0.2% Salinity: ±0.2% ATC
RHS-28BATC Salinity: 0-28%
Brix: 0-32%
Salinity:0.2%
Brix:0.2%
Salinity: ±0.2%
Brix: ±0.2%
ATC
RHS-35ATC Salinity: 0-35% Salinity: 0.5% Salinity: ±0.5% ATC, For Food,
                                          
Digital Salinity and Temperature Meter KS-12                                          
Specifications:
1. Range: 0% ~ 10% Salt; 0-90℃ (32-194 ℉)
2. Resolution: 0.01%; 0.1℃ / 0.2°F
3. Accuracy (23±5°C): 0%~2.9%(± 0.1-0.3%); 3.0%~4.9%(± 0.3-0.5%); 5.0%~10%(±0.5-1.0%)
4. Operating Temperature: 5~45°C (ATC)
5. Calibration One point: 3.5% Salt calibration buffer solution (3.5gKCL/100mL pure water)
6. Power supply: DC 4 x 1.5V ( LR44 )
Features:
1. Automatic switch-off: After 8-10 minutes without pushing buttons, the meter will be switched off automatic.
2. Data holding.
3. Size: 245x30x18mm
                                          
Pen Type pH/ Meter                          

Features: Auto calibration, Auto identification of standard solutions, Auto power-off, low voltage alarm, Auto temperature compensation, Auto switches of range, IP57 dustproof and waterproof

Model PE01 PE02 PE03 PE05 PE06 PE07
Description pH Meter Conductivity Tester TDS Meter ORP Meter Salinity Meter

Range

0~14.0pH 0~100.0μS/cm
0~1000μS/cm
0~10.00mS/cm
0~50.0 ppm
0~500 ppm
0~5.00 ppt
±1000mV 0~5.00ppt 0~100.00ppt
Resolution 0.1pH 0.1/1μS/cm
0.01mS/cm
0.1/1ppm
0.01ppt
1mV 0.01ppt 0.01/0.1ppt
Accuracy ±0.2pH ±1%FS ±1%FS ±0.5%FS ±1%FS ±1.5%FS
Calibration Solution:        YES                      YES                          YES NO YES
Power AAA batteries×2,1.5V×2
Dimension 39×25×176 mm
                                          
For Clinical Protein                                  
Model Range Min.Div. Accuracy Remark
VUR1T Serum Protein: 0-12g/dl
Urine Gravity: 1.000-1.040sg
Serum Protein:0.2g/dl
Specific Gravity:0.002sg
Serum Protein:±0.2g/dl
Specific Gravity:±0.002sg 
ATC
VUR2T Serum Protein: 0-12g/dl
Urine Gravity: 1.000-1.050sg
Refractive Index:1.3330-1.3600RI
Serum Protein:0.2g/dl
Specific Gravity:0.002sg
Refractive Index: 0.0005RI
Serum Protein:±0.2g/dl
Specific Gravity:±0.002sg
Refractive Index:±0.0005 
ATC
VUR3T Serum Protein: 0-12g/ml
Urine Gravity: 1.000-1.050UG
Refractive Index:1.3330-1.3600nD
Serum Protein:0.2g/ml
Specific Gravity:0.005UG
Refractive Index: 0.0005nD
Serum Protein:±0.2g/ml
Specific Gravity:±0.002UG
Refractive Index:±0.0005nD
ATC
VUR4T Serum Protein: 0-12g/dl
Urine Gravity: 1.000-1.040UG
Refractive Index:1.3330-1.3600nD
Serum Protein:0.2g/dl
Specific Gravity:0.005UG
Refractive Index: 0.0005nD
Serum Protein:±0.2g/dl
Specific Gravity:±0.002sg
Refractive Index:±0.0005nD 
ATC
                                          
For PET (CAT, DOG) Clinical Protein                                  
AMR016 Serum Protein/Plasma: 2-14gms/100ml
Cat Urine Gravity: 1.000-1.060
Dog Urine Gravity: 1.000-1.060
Serum Protein:0.1
Specific Gravity:0.001
Serum Protein:±0.1g/dl
Specific Gravity:±0.001sg
ATC
                                          
Automotive AdBlue / DEF Urea Concentration Test Meter                                   
Model Range Min. Div. Remark Size Weight
AMR001 Urea: 0-40%

0.2%

ATC, Urea 32.5% 27x40x160mm 175g
AMR002 Urea: 0-40% 0.2% ATC
EG: -60°F ~ 32°F 10°F
PG: -50°F ~ 0°F 10°F
AMR003

Urea: 0-40%

0.2%

EG: -50°C ~ 0°C

5°C

PG: -50°C ~ 0°C

5°C

CW: -40°C ~ 0°C

10°C
AMR004

Urea: 30-35%

0.2%

EG: -50°C ~ 0°C

5°C

PG: -50°C ~ 0°C

5°C

CW: -40°C ~ 0°C

10°C

BF: 1.10 ~ 1.40Kg/L

0.01Kg/L
                                          
For Milk         
Model Range Min. Div. Remark Size Weight
AMR005 Soybean Milk: 0-25%

0.5%

No ATC 27x40x150mm 175g
Brix: 0-32%

0.2%

AMR006 Water in Milk: 0-20% 0.2% No ATC
                                          
For Battery/Antifreeze/Cleaning Fluid         
Model Range Min.Div. Accuracy Remark
RHA-100 Ethylene Glycol: -84° F-32°F
Propylene Glycol:-60° F-32°F
Battery: 1.100-1.400sg
Ethylene Glycol: 5°F
Propylene Glycol: 5°F
Battery: 0.01sg
Ethylene Glycol: ±5° F
Propylene Glycol: ±5° F
Battery: ±0.01sg
Without ATC
RHA-100ATC Ethylene Glycol: -84° F-32°F
Propylene Glycol:-60° F-32°F
Battery: 1.100-1.400sg
Ethylene Glycol: 5°F
Propylene Glycol: 5°F
Battery: 0.01sg
Ethylene Glycol: ±5° F
Propylene Glycol: ±5° F
Battery: ±0.01sg
ATC
RHA-200 Ethylene Glycol:-60°C-0°C
Propylene Glycol:-50°C-0°C
Battery:1.100-1.400sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Battery: 0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Battery: ±0.01sg
Without ATC
RHA-200ATC Ethylene Glycol:-60°C-0°C
Propylene Glycol:-50°C-0°C
Battery: 1.100-1.400sg
Ethylene Glycol:5°C
Propylene Glycol:5°C
Battery:0.01sg
Ethylene Glycol:±5°C
Propylene Glycol:±5°C
Battery:±0.01sg
ATC
RHA-300F Ethylene Glycol:-60°F-32°F
Propylene Glycol:-50°F-32°F
Battery: 1.15-1.30sg
Ethylene Glycol: 10°F
Propylene Glycol: 10°F
Battery: 0.01sg
Ethylene Glycol: ±10°F
Propylene Glycol: ±10°F
Battery: ±0.01sg
Without ATC
RHA-303 Ethylene Glycol:-70°C-0°C
Propylene Glycol:-60°C-0°C
Battery:1.100-1.400sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Battery: 0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Battery: ±0.01sg 
Without ATC
RHA-403C Ethylene Glycol: -50°C-0°C
Propylene Glycol: -50°C-0°C
Battery: 1.15-1.30sg
Cleaner: -40°C-0°C
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Battery: 0.01sg
Cleaner: 5°C
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Battery: ±0.01sg
Cleaner: ±5°C
Without ATC
RHA-501 Battery: 1.10sg-1.40sg
Ethylene Glycol: -60°F-32°F
Ethylene Glycol: -50°C-0°C
Propylene Glycol: -50°C-0°C
Propylene Glycol: -50°F-32°F
Battery: 0.01sg
Ethylene Glycol: 10°F
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Propylene Glycol: 10°F
Battery: ±0.01sg
Ethylene Glycol: ±10°F
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Propylene Glycol: ±10°F
Without ATC
RHA-503C Battery: 1.100-1.400sg
Ethylene Glycol: -50°C-0°C
Propylene Glycol: -50°C-0°C
Cleaner: -40°C-0°C
Battery: 0.01sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Cleaner: 5°C
Battery: ±0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Cleaner: ±5°C
 ATC
RHA-800 B:1.000~1.400sg
A:0%~100%
F:-60°C~0°C
0.01sg
5%
5°C
±0.01sg
±5%
±5°C
Without ATC
RHA-800ATC B:1.000~1.400sg
A:0%~100%
F:-60°C~0°C
0.01sg
5%
5°C
±0.01sg
±5%
±5°C
ATC
                                          
For Brake Check                                      
Model Range Min.Div. Remark Size
VBK1 DOT3: 1-6% Moisture
          Boiling Point: 250-500°F
Super DOT3: 1-6% Moisture
          Boiling Point: 250-570°F
1% ATC 40 x 40 x 220mm
VBK2 DOT3: 1-6% Moisture
          Boiling Point: 125-275°C
Super DOT3: 1-6% Moisture
          Boiling Point: 150-275°C
1% ATC 40 x 40 x 220mm
                                     
AM001 Brake Fluid Tester             
Features:

* Test dot 3 & 4 brake fluid (dot 5 for ref. only)
* 5 LED to indicate percent of water in the brake fluid.
* Batteries: 1x 1.5V AAA
* Immerse tester probe into brake fluid, press the button and for about 2 seconds the test result is indicated on the lightest diodes.
* Green: Battery OK
* Green/Yellow: Water content<1%
* Green/Yellow/Yellow: Water content ≈2%
* Green/Yellow/Yellow/Red: Water content ≈3%, change brake fluid
* Green/Yellow/Yellow/Red/Red: Water content ≥ 4%,change brake fluid urgently

                                          
For Alcohol                                              
Model Range Min.Div. Accuracy Remark
RHW-80 w/w: 0-50%, 50-80% 0-50%: 1%; 50-80%: 2.5% ±1% Without ATC
RHW-25ATC 0-25% VOL; Brix: 0-40% 0.2% ±0.2% ATC
                                          
For Refractive Index                            
Model Range Min.Div. Accuracy Remark
VND1 nD.1.333-1.520 0.001 ±0.002 ATC
VND2 nD.1.333-1.380 0.001 ±0.002 ATC
VND4 nD.1.435-1.520 0.001 ±0.002 ATC
                                          
For Bee Honey                                      
Model Range Min.Div. Accuracy Remark
RHH13-25 water: 13-25% water:0.1% water:±0.1% ATC
RHH12-30 water: 12-30% water:0.1% water:±0.1% ATC
RHH-92ATC Brix: 58-92%
Baume: 38-43Be'
water: 12-27%
Brix: 0.5%
Baume: 0.5Be'
water: 1%
Brix: ±0.5%
Baume: ±0.5Be'
water: ±1%
ATC
                                          
For Grape                                             
Model Range Min.Div. Accuracy Remark
RHW-25aATC Alcohol:0-25%VOL
Baume: 0-20Baume 
Alcohol:0.2%
Baume: 0.2 be° 
Alcohol:±0.2%
Baume: ±0.2 be° 
ATC
RHW-25ATC Alcohol:0-25%  Alcohol:0.2%  Alcohol:±0.20%  ATC
RHW-25bATC Alcohol:0-25%VOL
Brix: 0-40%
Alcohol:0.2%
Brix: 0.2%
Alcohol:±0.2%
Brix: ±0.2%
ATC
                                          
For Emulsion                                             
Model Range Min.Div. Accuracy Remark
AMR011 M10: 0-15%
MDT: 0-15% 
0.5%  Alcohol:±0.5% ATC
                                          
For Contact Lens                                             
Model Range Min.Div. Accuracy Remark
AMR011 35~80% 1%  Alcohol:±1% without ATC
                                          
For IPA (Iso-Propyl Alcohol)                   
Model Range Min.Div. Accuracy Remark
AMR015 0~60% (v/v) 1% 

±1%

 
-23°C~0°C 1°C

±1°C

 
                                          
For °OE                                                
Model Range Min.Div. Accuracy Remark
RHBS-32aATC Brix: 0-32%
Oechsle: 30-140°Oe
Brix: 0.2%
Oechsle: 1.0°Oe
Brix: ±0.2%
Oechsle: ±1.0°Oe
ATC
RHBS-32ATC Brix: 0-32%Mas Sacch
Oechsle: 0-140°Oe
KMW: 0-27°(Babo)
Brix: 0.2%
Oechsle: 1.0°Oe
KMW: 0.2°
Brix: ±0.2%
Oechsle: ±1.0°Oe
KMW: ±0.2°
ATC
RHBS-44ATC Brix: 0-44%
Oechsle: 0-190°Oe
KMW: 0-38°(Babo)
Brix: 0.4%
Oechsle: 2.0°Oe
KMW: 0.4°
Brix: ±0.4%
Oechsle: ±2.0°Oe
KMW: ±0.4°
ATC
                                          
For Gem                                               
Refractive index is one of most important optical parameter. Gloss of gem can be estimated by the parameter.
The kinds of gem can be precisely determined in accordance with the measured value of refractive index because every kind of gem has its inherent refractive. Besides, index of double refraction can be also measured. Through the parameter you can judge whether a gem is uniaxial or biaxial photopositive or photonegative.
The gemological refractometer is characterized by small volume and less weight. It is easy to carry. It is a popular instrument used in jewelery market.
Model Range Min. Div. Size N.W.
RHG-181 Refractive Index: 1.30-1.81 Refractive Index: 0.01 30x30x130mm 400g
                                          
Economic Plastic Refractometer
For Brix                                                  
Model Range Min.Div. Accuracy Remark
RPB-32 Brix: 0-32% Brix: 0.2% Brix: ±0.20%  
                                          
For Salinity                                            
Model Range Min.Div. Accuracy Remark
RPS-10 Salinity: 0-100‰
Gravity: 1.000-1.070 
Salinity: 1‰
Gravity: 0.001
Salinity: ±0.001
Specific gravity: ±0.001 
 
RPS-28 Salinity: 0-28% Salinity: 0.2% Salinity: ±0.2%  
                                          
For Battery/Antifreeze/Cleaning Fluid         
Model Range Min.Div. Accuracy Remark
RPA-100 Ethylene Glycol: -84° F-32°F
Propylene Glycol:-60° F-32°F
Battery: 1.100-1.400sg
Ethylene Glycol: 5°F
Propylene Glycol: 5°F
Battery: 0.01sg
Ethylene Glycol: ±5° F
Propylene Glycol: ±5° F
Battery: ±0.01sg
 
RPA-200 Ethylene Glycol:-60°C-0°C
Propylene Glycol:-50°C-0°C
Battery:1.100-1.400sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Battery: 0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Battery: ±0.01sg
 
RPA-503C Battery: 1.100-1.400sg
Ethylene Glycol: -50°C-0°C
Propylene Glycol: -50°C-0°C
Cleaner: -40°C-0°C
Battery: 0.01sg
Ethylene Glycol:5°C
Propylene Glycol: 5°C
Cleaner: 5°C
Battery: ±0.01sg
Ethylene Glycol: ±5°C
Propylene Glycol: ±5°C
Cleaner: ±5°C
 
                                          
Atago Digital Rfractometer PEN-PRO                               
The PEN-PRO has a measurement range of Brix 0.0 to 85.0% which can be used to measure almost any sample. There are 2 ways to measure with the PEN-PRO. Either dip the tip into the sample and press the START key OR press the START key and touch the tip into the sample. There is also the new feature to perform continuous measurements. The temperature range of the "Dip-Type" Refractometer PEN-PRO has been improved from 60°C to 100°C. No more wait ! Measure hot samples while in the cooking process, such as soups and sauces.  

Model PEN-PRO Cat. No. 3730
Measurement Range Brix 0.0 to 85.0% Minimum Indication Brix 0.1%
Measurement Accuracy Brix ±0.2% Measurement Temperature 10 to 100°C (Automatic Temperature Compensation )
Ambient Temperature 10 to 40°C Power Supply 1 × Size AAA alkaline battery
International Protection Class IP65 Dust-tight and Protected against water jets. Prism head IP67 Dust-tight and Protected against the effects of temporary immersion in water.
Measurement Time 2 seconds Dimensions & Weight 16×3.8×1.8cm, 70g, (Main Unit only)
Optional • USB BATTERY CHARGER : RE-34801
• STRAP : RE-39410
Features
Ergonomically designed for one-handed operation. Protection class of the PEN is IP65 (Prism head IP67). You can rinse off the sample by running water on the prism. The design allows the user to easily wipe off the sample.
The Automatic Temperature Compensation function of the PEN enable you to take measurement readings regardless of the ambient temperature. Revolutionary new feature ELI*
*External Light Interference (ELI) - Patent Pending.
Convenient Storage case. High temperature sample can be measured.
*Do not dip the instrument directly into a boiling pot to measure; instead, place the liquid in a separate container and measure.
                                          
Digital Type (I)                               

Digital Refractometer is a kind of digit product based on the hand-held refractometer. The digit can be displayed and equipped with ATC.

1. Temperature Measurement Range: 0°C-40°C (32-104°F)
2. Precision of Measurement temperature:±1°C(2°F)
3. Measurement temperature Resolution:0.1°C
4. Operation Temperature:0-35°C(32-9°F)
5. Storage temperature:0-50°C (32-122°F)
6. Dimension:185×59×45mm
7. Weight: 230g
8. Power Supply: 1battery (9v)
9. Operating Time: More than 2000 times per battery
10. Automatic Temperature Compensation
11. Automatic Shut Off
12. Conversion between Centigrade and Fahrenheit Degree
13. Alarm of Low Voltage

 

                                          
For Brix                                                
Model Scale Range Div. Accuracy
DRB0-45 Brix 0-45% 0.1% ±0.2%
DRB0-45nD Brix
Refractive Index
0-45%
1.3330-1.4098
0.1%
0.0001
±0.2%
±0.0003
DRB28-65 Brix 28-65% 0.1% ±0.2%
DRB28-65nD Brix
Refractive Index
28-65%
1.3770-1.4535
0.1%
0.0001
±0.2%
±0.0003
DRB58-92 Brix 58-92% 0.1% ±0.2%
DRB58-92nD Brix
Refractive Index
58-92%
1.4370-1.5090
0.1%
0.0001
±0.2%
±0.0003
DRBS-300 Brix
Salinity
Refractive Index
0-35%
0-28%
1.3330-1.3900
0.1%
0.1%
0.0001
±0.2%
±0.2%
±0.0003
                                          
For Salinity                                          
Model Scale Range Div. Accuracy
DRS0-28 Salinity 0-28% 0.1% ±0.2%
DRS0-28nD Salinity
Refractive Index
0-28%
1.3330-1.3900
0.1%
0.0001
±0.2%
±0.0003
DRBS-300 Brix
Salinity
Refractive Index
0-35%
0-28%
1.3330-1.3900
0.1%
0.1%
0.0001
±0.2%
±0.2%
±0.0003
                                          
For Clinical Protein                             
Model Scale Range Div. Accuracy
DRC-200

Urine Gravity
Serum Protein
Refractive Index

1.000-1.050
0-12g/dl
1.3330-1.3900
0.001
0.1
0.0001
±0.001
±0.1
±0.0003
                                          
For Battery/Antifreeze/Cleaning Fluid     
Model Scale Range Div. Accuracy
DRA-403C

Propylene Glycol
Ethylene Glycol
Battery
Cleaner

-95-0 ℃
-70-0 ℃
1.000-1.510sg
-72-0 ℃
0.1 ℃
0.1 ℃
0.01sg
0.1 ℃
±0.20 ℃
±0.20 ℃
±0.01sg
±0.20 ℃
DRA-403F

Propylene Glycol
Ethylene Glycol
Battery
Cleaner

-130-32 ℉
-95-32 ℉
1.000-1.510sg
-100-32 ℉
0.1 ℉
0.1 ℉
0.01sg
0.1 ℉
±0.5 ℉
±0.5 ℉
±0.01sg
±0.5 ℉
                                          
For °OE                                                    
Model Scale Range Div. Accuracy
DRB-400

MASS s/v
Vol AP
Oe
KMW

0-35%
0-22%
0-150
0-25
0.1%
0.1%
1.0
0.1
±0.2%
±0.2%
±1.0
±0.2
                                          
For Bee Honey                                        
Model Scale Range Original Point Div. Accuracy
DRH-300

nD
°Be′
WATER

1.4419-1.5232
33.1-47.7
38.4%-5.4%
1.4419(±0.0001)
33.1
38.4
0.0001
0.1
0.1%
±0.0003
±0.2%
±0.2%
                                          
Digital Type (II)                                     

Digital Refractometer is a kind of digit product based on the hand-held refractometer. The digit can be displayed and equipped with ATC.

1. Working Temp. Range: 0°C-40°C (32-104°F)
2. Power Supply: 2 x AAA battery
3. Automatic Temperature Compensation 5~40℃
4. Automatic Shut Off
5. Size: 135 x 65 x 40mm, weight: 200g
6. Compact, robust and pocket size
7. Multi Scale versions
8. High accuracy

Model SCALE Range Division Accuracy

DBR85

BRIX

0~85%

0.1

+-0.2

REFRACTIVE INDEX

1.3330~1.5100

0.0001

+-0.0003

DBR35 BRIX 0~35% 0.1 +-0.2

REFRACTIVE INDEX

1.3330-1.3900

0.0001

+-0.0003

DBR45 BRIX 0~45% 0.1 +-0.2

REFRACTIVE INDEX

1.3330~1.4098

0.0001

+-0.0003

DBR65 BRIX 28~65% 0.1 +-0.2

REFRACTIVE INDEX

1.3770~1.4535

0.0001

+-0.0003

DBR92 BRIX 58~92% 0.1 +-0.2

REFRACTIVE INDEX

1.4370~1.5233

0.0001

+-0.0003

DBR95

BRIX

0~95% 0.1 +-0.5

REFRACTIVE INDEX

1.3330~1.5400 0.0001 +-0.0003

DHN1
(Honey IHC2002)

BRIX 58-92% 0.1 +-0.2
BAUME 38-43 0.1 +-0.1
WATER 13-25 0.1 +-0.1
REFRACTIVE INDEX 1.4370-1.5233 0.0001 +-0.0003

DHN2
(Honey GB)

BRIX 58-92% 0.1 +-0.2
BAUME 38-43 0.1 +-0.1
WATER 17-27 0.1 +-0.1
REFRACTIVE INDEX 1.4370-1.5233 0.0001 +-0.0003
DSA1 SALINITY 0~28% 0.1 +-0.2

REFRACTIVE INDEX

1.3330-1.3900

0.0001

+-0.0003

DSA2

SEA WATER

0~100PPT

1

+-0.2

SG

1.000~1.070

0.0001

+-0.0003

DSA3

NaCl

0~35%

0.1

+-0.2

DUR1 URINE SP.G 1.000~1.050 0.001 +-0.001

SERUM P. (g/dl)

0-12

0.1

+-0.1

REFRACTIVE INDEX

1.3330-1.3900

0.0001

+-0.0003

DUR2

SERUM P. (g/dl) 0-14 0.1 +-0.1
URINE SP.G.(DOG) 1.000~1.060 0.001 +-0.001
REFRACTIVE INDEX 1.3330-1.3900 0.0001 +-0.0003

DUR3

SERUM P. (g/dl) 0-14 0.1 +-0.1
URINE SP.G.(CAT) 1.000~1.060 0.001 +-0.001
REFRACTIVE INDEX 1.3330-1.3900 0.0001 +-0.0003
DAL1 Ethanol (Alcohol) 0~60% (v/v) 0.1 +-0.3
DAL2 Ethanol (Alcohol) 0~60% (w/w) 0.1 +-0.3
DAL3 IPA 0~60% (w/w) 0.1 +-0.5
DAL5 Methanol 0~60% (w/w) 0.1 +-0.5
DAL6 IPA 0~40% (v/v) 0.1 +-0.5
DMK1 Soybean Milk 0~35% 0.1 +-0.3
DMK2 Butyro 30~90% 0.1 +-0.5
DWN1 MASS S/W 0~35% 0.1 +-0.2

VOL AP

0~22%

0.1

+-0.1

OESCHLE (°OE) (Germany)

0-150

1

+-1

°KMW

0-25

0.1

+-0.1

DWN2

MASS S/W 0~35% 0.1 +-0.2

VOL AP

0~22%

0.1

+-0.1

OESCHLE (°OE)

30-150

1

+-1

°KMW

0-25

0.1

+-0.1

DWN3

MASS S/W

0~35% 0.1 +-0.2

VOL AP

0~22% 0.1 +-0.1

OESCHLE (°OE) (Swiss)

0-150 1 +-1

°KMW

0-25 0.1 +-0.1
DBS1 BRIX 0~35% 0.1 +-0.2

SALINITY

0~28%

0.1

+-0.2

REFRACTIVE INDEX

1.3330~1.3900

0.0001

+-0.0003

DBC1

PROPYLENE GLYCOL

32~-50 0.1 +-1

ETHYLENE GLYCOL

32~-50 0.1 +-1

BATTERY

1.00-1.50sg 0.01sg +-0.01sg

CLEANER

14~-40 0.1 +-1

DBC2

PROPYLENE GLYCOL

0 ~ -50 0.1℃ +-0.5℃

ETHYLENE GLYCOL

0 ~ -50 0.1℃ +-0.5℃

BATTERY

1.00-1.50sg 0.01sg +-0.01sg

CLEANER

0 ~ -40 0.1℃ +-0.1℃

DBC3

PROPYLENE GLYCOL

0 ~ 70% 0.1% +-0.3%

ETHYLENE GLYCOL

0 ~ 80% 0.1% +-0.3%

AMR009

Urea (AdBlue)

0 ~ 40% 0.1% +-0.2

PROPYLENE GLYCOL

0 ~ -50 0.1℃ +-0.5℃

ETHYLENE GLYCOL

0 ~ -50 0.1℃ +-0.5℃

CLEANER

0 ~ -40 0.1℃ +-0.5℃

AMR010

Urea (AdBlue)

0 ~ 40% 0.1% +-0.2

DND

REFRACTIVE INDEX

1.3330~1.5400 0.0001 +-0.0003
                                          
Digital Refractometer AMR serials                                   
The AMR serials refractometer is an optical instrument that employs the measurement of refractive index to determine the concentration in aqueous solutions. The method is both simple and quick.
Samples are measured after a simple user calibration with deionized or distilled water.
Within seconds the instrument measures the refractive index of the sample and converts it to %  concentration units.
The AMR digital refractometer eliminates the uncertainity associated with mechanical refractometers and is easily portable for measurements in the field.
The measurement technique and temperature compensation employ methodology recommended in the internationally standard.
Temperature (in °C or °F) is displayed simultaneously with the measurement on the large dual level display along with icons for Low Power and other helpful message codes.
Key features include:
1. Dual-level LCD
2. Automatic Temperature Compensation (ATC)
3. Easy setup and storage
4. Battery operation with Low Power indicator (BEPS)
5. Automatically turns off after 3 minutes of non-use.

                                          
Digital Brix Refractometer AMR100                                   
Specifications:
Range: 0~85% Brix; 0~80°C / 32~175°F
Resolution: 0.1% Brix; 0.1°C / 0.1°F
Accuracy: ±0.2% Brix; ±0.3°C / ±0.5°F
Light Source: Yellow LED
Measurements Time: Approximately 1.5 seconds
Minimum Sample Volume: 100
µl (cover prism totally)
Sample Cell: SS ring and flint glass prism
Temperature Compensation: Automatic between 10 and 40°C / 50 to 104°F
Case Material: ABS
Enclosure Rating: IP65
Battery Type: 1 x 9V
Auto-shut off: after 3 minutes of non-use
Dimensions: 192 x 102 x 67 mm
Weight: 420g
                                          
Digital Sodium Chloride (NaCl) Refractometer AMR101                                   
SPECIFICATIONS
 Range: 0~28g/100g; 0~34g/100ml; 1.000~1.216 Specific Gravity; 0~26° Baume; 0~80°C / 32~175°F
 Resolution: 0.1 g/100g; 0.1 g/100ml; 0.001 Specific Gravity; 0.1 ° Baume; 0.1°C / 0.1°F
 Accuracy: ±0.2 g/100g; ±0.2 g/100ml; ±0.002 Specific Gravity; ±0.2° Baume; ±0.3°C/±0.5°F
 Light Source: Yellow LED
 Measurements Time: Approximately 1.5 seconds
 Minimum Sample Volume: 100µl (cover prism totally)
 Sample Cell: SS ring and flint glass prism
 Temperature Compensation: Automatic between 10 and 40°C / 50 to 104°F
 Case Material: ABS
 Enclosure Rating: IP65
 Battery Type: 1 x 9V
 Auto-shut off: after 3 minutes of non-use
 Dimensions: 192 x 102 x 67 mm
 Weight: 420g
                                          
Digital Sea Water (NaCl) Refractometer AMR102                                   
SPECIFICATIONS
 Range: 0~50PSU; 0~150ppt; 1.000 to 1.114 S.G. (20/20); 0~80°C/32~175°F;
 Resolution: 1PSU; 1ppt; 0.001 S.G. (20/20); 0.1°C / 0.1°F;
 Accuracy: ±2PSU; ±2ppt; ±0.002 S.G. (20/20); ±0.3°C / ±0.5°F
 Light Source: Yellow LED
 Measurements Time: Approximately 1.5 seconds
 Minimum Sample Volume: 100µl (cover prism totally)
 Sample Cell: SS ring and flint glass prism
 Temperature Compensation: Automatic between 10~40°C / 50~104°F
 Case Material: ABS
 Enclosure Rating: IP65
 Battery Type: 1 x 9V
 Auto-shut off: after 3 minutes of non-use
 Dimensions: 192 x 102 x 67 mm
 Weight: 420g
                                          
Digital Grape Wine Refractometer AMR103                                   
SPECIFICATIONS
Range: 0~50% Brix; 0~25% v/v Potential Alcohol; 0~80°C / 32~175°F
Resolution: 0.1% Brix; 0.1% v/v Potential Alcohol; 0.1°C / 0.1°F
Accuracy: ±0.2% Brix; ±0.2 v/v Potential Alcohol; ±0.3°C / ±0.5°F
Light Source: Yellow LED
Measurements Time: Approximately 1.5 seconds
Minimum Sample Volume: 100 µl (cover prism totally)
Sample Cell: SS ring and flint glass prism
Temperature Compensation: Automatic between 10 and 40°C / 50 to 104°F
Case Material: ABS
Enclosure Rating: IP65
Battery Type: 1 x 9V
Auto-shut off: after 3 minutes of non-use
Dimensions: 192 x 102 x 67 mm
Weight: 420g
                                          
Abbe Refractometer                          

 

1) WYA Abbe Refarctomter
Features
1. Measurement of refractive index nD, average dispersion nF-nC of transparent or translucent liquid and solid substances.
2. Measurement of mass fraction (Brix) of cane sugar solution.
3. This Abbe Refractometer is used in the field of sugar, pharmaceutical, beverage, petroleum, food, chemical industries as well as research institutes and educational department.
4. It offers visual aim, optical index-plate reading.
Specifications
Refractive index nD: 1.3000-1.7000
Accuracy: ±0.0002
Dissolved Solids Brix: 0-95%
G.W.: 3.5 kg
Dimensions: 270*180*370mm
2) WYA-2W Abbe Refarctomter
Features
1. Measurement of refractive index nD, average dispersion nF-nC of transparent or translucent liquid and solid substances.
2. Measurement of mass fraction (Brix) of cane sugar solution.
3. The WYA-2W Abbe Refractometer is used in the field of sugar, pharmaceutical, beverage, petroleum, food, chemical industries as well as research institutes and educational department.
4. It offers visual aim, optical index-plate reading.
Specifications
Refractive index nD: 1.3000-1.7000
Accuracy: ±0.0003
Dissolved Solids Brix: 0-95%
Magnification of the telescope objectives: 2X
Magnification of the reading objectives: 22X
Weight (Gross):4.5 kg
Overall Dimensions: 240*200*390mm
3) 2WAJ Abbe Refractometer           

This monocular Abbe instrument is designed for the measurement of refractive index (nD) and the average optical dispersion (NF-NC) of the transparent, the semitransparent and the solid matter (mostly transparent). It was connect with a circulating thermostatic bath, can measure the refractive index in 0℃~70℃.

Refractive index and the average optical dispersion are important constant among physical constants. They can indicate the optical property of purify rate, concentration and size of optical dispersion of materials. It also measures the Brix percentage of sugar solution(0%~95% which is equal to the refractive index1.333-1.531).

It was widely used in oil industry, fat industry, pharmaceutical factories, paint, food processing, chemistry, sugar refineries, geologic etc., and relative factories, school and research center.

Model 2WAJ
Refractive Index (nD) Range 1.300~1.700
Refractive Index (nD) Accuracy ±0.0002
Refractive Index (nD) Min. Div. 0.0005
Brix (%) Range (0~95)%
Brix (%) Min. Div. 0.25%
Size (mm) 90x190x250
Weight (KG) 3
4) WYA-2S Digital Abbe Refractometer
  • Measurement of refractive index nD of transparent or translucent liquid and solid substances.
  • Measurement of the Brix of sugar solution.
  • Visual aim and LCD display
  • Automatic correction of the effect of temperature on the Brix.
  • Prism made of hard glass, uneasy to be worn.
  • Printer interface for direct data print-out.

Model WYA-2S WYA-3S
Refractive Index (nD) Range 1.3000~1.7000 1.30000~1.72000
Refractive Index (nD) Accuracy ≤±0.0002
Brix (%) Range 0~100%
Brix (%) Accuracy ≤±0.1%
Resolution Brix:0.1%, nD:0.0001 Brix:0.01%, nD:0.00001
Temperature Range 0-50°C -20-120°C
Measuring Mode ----- 8
Display LCD Colorful Touch Screen
Interface RS232 RS232/USB
Storage ----- 500groups
Size 330 x 180 x 380mm
Weight 10Kg
5) SWYA-2S Digital Abbe Refractometer
  • Measurement of refractive index nD of transparent or translucent liquid and solid substances.
  • Measurement of the Brix of sugar solution.
  • Visual aim and LCD display
  • Automatic correction of the effect of temperature on the Brix.
  • Can connect with water bath.
  • Printer interface for direct data print-out.
  • N.W.: 8Kg
  • Size: 33 x 18 x 38cm
     

Model SWYA-2S
Refractive Index (nD) Range 1.3000~1.7000
Refractive Index (nD) Accuracy ≤±0.0002
Brix (%) Range (0~95)%
Brix (%) Accuracy ≤±0.1%
Temperature Range 0-50℃
 
6) WYA-Z, WYA-ZL, WYA-ZT Automatic Digital Abbe Refractometer
Characteristics:
1. Full automatic measuring, avoid personal error
2. Touch Screen
3. Have the function of temperature display, automatic correction and saving the date
4. Thermostatical control, temperature automatic correction and saving the data (Model WYA-ZT)
5. Can be connected with water bath. (Model WYA-ZL)
6. RS232

Specifications:
Measuring range:
 1) Refractive index nD: 1.30000-1.70000
 2) Brix (BX-TC): 0-95%
 3) Brix (BX): 0-95%
Measuring accuracy:
 1)Refractive index nD: ±0.0002
 2) Dissolved solids Brix: ±0.1%
Measuring resolution:
 1) Refractive index nD: 0.00001
 2) Dissolved solids Brix: 0.01%
Temperature:
 1) Temperature display range: 0-50℃
 2) Thermostatical control range: room temperature ± 10℃ (WYA-ZT)
Weight: 3kgs
Overall dimensions: 329 x 214 x 150mm