LOW-SPEED CENTRIFUGE FOR SAMPLE SEPARATION
The DT5-3 low-speed centrifuge separates components in mixed samples by centrifugal force. It is designed for medical and scientific research settings and supports multiple rotor configurations for different tube and plate formats. Choose a rotor to match your sample vessels and required operating range.
1. Speed up to 5,000 rpm — maximum speed up to 5,000 rpm, depending on the installed rotor
2. Seven rotor configurations — for tubes, 100 mL vessels, and 96-well plates
3. Clear readout — displays speed, time, relative centrifugal force (RCF), and rotor number
4. Countdown timer — automatic stop when the set time is reached
5. Safety protection — lid interlock prevents operation while the lid is open; rotor stall or overspeed protection stops the unit and sounds an alarm
The control panel allows the operator to set speed, run time, RCF, and rotor number, and the display shows these operating values. At the end of the set time the centrifuge stops automatically.
Control panel and display |
Rotor inside the chamber |
Rotor speed and RCF limits vary by configuration. Use the limits shown for the selected rotor.
| Rotor | Capacity | Maximum speed | Maximum RCF | Configuration |
| Rotor 1 | 10 mL × 8 × 4 | 3,500 rpm | 4,360 × g | Standard |
| Rotor 2 | 5 mL × 12 × 4 | 4,200 rpm | 4,360 × g | Standard; blood tubes |
| Rotor 3 | 2 mL × 48 | 3,500 rpm | 4,360 × g | Standard; tube adapter |
| Rotor 4 | 100 mL × 4 | 5,000 rpm | Not specified | Optional |
| Rotor 5 | 10 mL × 3 × 4 | 5,000 rpm | Not specified | Optional |
| Rotor 6 | 5 mL × 15 × 4 | 4,200 rpm | Not specified | Optional |
| Rotor 7 | 96-well plates × 2 | 2,000 rpm | Not specified | Optional |
| Speed and RCF | Maximum speed up to 5,000 rpm, rotor-dependent; maximum RCF up to 4,360 × g for Rotors 1–3 |
| Speed accuracy | ±1% |
| Timer | 0–999 min / ±1 min |
| Noise and rotation | Noise level ≤65 dB; rotation direction counterclockwise |
| Power supply | Single-phase AC 220 V ±22 V, 50 Hz ±1 Hz; standard sine wave |
| Operating environment | 5–40 °C; ≤80% RH at 25 °C; free of conductive dust, explosive gases, and corrosive gases |
| Sample and weight | Sample solution density ≤1.2 g/cm³; net weight 35 kg |
| Storage conditions | −40 to 70 °C; ≤80% RH; 500–1,060 hPa |
1. Medical treatment — sample separation in medical treatment workflows
2. Scientific research — select the rotor configuration according to the tube, vessel, or plate format being used