PRODUCTS
CONTACT US
TEL: +86-532-85754589,85775618
FAX: E-Mail
E-MAIL: tlead.net@gmail.com; tlead.net@hotmail.com

BENCHTOP TURBIDITY METER FOR LABORATORY USE
The TB200 benchtop turbidity meter measures turbidity in NTU, FNU, EBC, and ASBC units, with a selectable total suspended solids (TSS) mode in mg/L. It uses a 90-degree nephelometric measurement method, supports 2- to 7-point calibration, and stores up to 200 readings for review or transfer to a computer.
1. Wide range — measures turbidity from 0 to 2,000 NTU/FNU, with selectable EBC and ASBC units
2. TSS mode — supports a TSS measurement mode using a user-set conversion factor
3. Calibration — offers 2- to 7-point calibration with Formazin standards; factory calibration is provided
4. Auto-read and storage — auto-read senses a stable value and locks the reading; store up to 200 records and transfer them to a computer over USB
5. Display and protection — includes a 4.5-inch TFT LCD, password protection for setup and calibration, and adjustable display brightness
The display shows the measured value with the active unit, and the keypad below it carries the escape, calibration, and navigation keys. The sample vial is placed in the compartment under the lid.
Display and keypad |
Sample vial in the compartment |
| Model | TB200 |
| Measurement method | ISO 7027 nephelometric method (90°) |
| Turbidity range | 0–2,000 NTU/FNU; 0–500 EBC; 0–9,999 ASBC |
| TSS measurement | Range depends on the selected conversion factor; resolution 0.1 / 1 mg/L; accuracy ±3% of reading; conversion factor 0.13 default, adjustable |
| Resolution and accuracy | Selectable 0.01, 0.1, 1 NTU or automatic (0.01 NTU 0–99; 0.1 NTU 100–999; 1 NTU 1,000–2,000); accuracy ±2% of reading (0–500 NTU), ±3% of reading (501–2,000 NTU) |
| Calibration | 2–7 points; standards: 0.02, 10, 200, 500, 1,000, 1,500, and 2,000 NTU |
| Optics | Infrared-emitting diode, 850 nm; silicon photodiode detector; stray light below 0.02 NTU |
| Data and communication | Data memory 200 measurement records; USB-B interface to computer; DAS data acquisition software |
| Display and sample | 4.5-inch TFT LCD; sample vial 60 mm high × 25 mm diameter; sample volume 30 mL |
| Power requirements | DC 12 V / 2 A power adapter |
| Operating conditions | 0–50 °C (32–122 °F); relative humidity below 80%, non-condensing |
| Storage conditions | 0–60 °C (32–140 °F) |
| Dimensions and weight | 250 × 177 × 96 mm (9.8 × 6.9 × 3.7 in.); 1.2 kg (2.6 lb) |
| Automatic power-off | 2 hours after the last keypress by default; can be disabled |
Users can select the measurement mode and unit, store readings in the meter, review saved records, and transfer stored data to a computer through the USB interface. The free DAS software transfers results and can save them as an Excel file. The meter also provides a measurement lock, date and time settings for records, password protection, and a reset function.
1. Laboratory use — turbidity and TSS measurements for food and beverage, environmental, agricultural, and chemical applications, as well as laboratory and scientific research workflows
2. Included in the package — TB200 turbidity meter, Formazin standards (0.02, 200, 500, and 1,000 NTU), two sample vials, lint-free cloth, and a DC 12 V power adapter
💡 Need a turbidity meter for your laboratory?
Contact our sales team today for bulk pricing, technical support, or to request a demo unit.
Or Email us: tlead.net@hotmail.com